SERIAL NUMBER (located on top of product):
PATENTS: U.S. 09642426, U.S. 06106246, U.S. 05971402, U.S. 05370507 07/27/12 MM50R-X12-F
Phone: 800-669-1303 or 801-561-0303
Fax: 801-255-2312
MAXIM 50R-X12 PUMP
Operation / Maintenance
Manual
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - MAXIM 50R-X12 PUMP

SERIAL NUMBER (located on top of product): PATENTS: U.S. 09642426, U.S. 06106246, U.S. 05971402, U.S. 05370507 07/27/12 – MM50R-X12-F Phone: 800-6

Page 2 - CONTENTS

PAGE 10 MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL 4 MAINTENANCE Trebor pump maintenance can be divided into two categories: air system main

Page 3 - 1 INSTALLATION

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 11 MAXIM 50R Maintenance Schedule Install 30 Days 3 Months 6 Months 9 Months 12 Months 15 Mont

Page 4

PAGE 12 MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL 4.1.a Preventive Maintenance Record Company Name: _______________________________________

Page 5 - 1.3 REMOTE EXHAUST HOOK-UP

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 13 4.2 RECOMMENDED SPARE PARTS KR50R-00-A Spares Rebuild Kit, which includes: Part No Qty Desc

Page 6 - 2 OPTIONS

PAGE 14 MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL 4.4 PARTS ILLUSTRATION

Page 7 - 2.3 OPTIONAL LEAK SENSING

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 15 4.5 PARTS LIST ILL NO PART NO QTY DESCRIPTION PM YEAR # MATERIAL 1 AM075 1 Damper Plug PTF

Page 8 - 3 START-UP

PAGE 16 MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL 4.7 DISASSEMBLY During the life of the pump it will be necessary to perform certain preve

Page 9

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 17  Remove head and check diaphragms for cracks or cuts.  To remove diaphragms, slit diaphr

Page 10 - 4 MAINTENANCE

PAGE 18 MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL 4.7.d Cleaning  Gently spray clean or dunk rinse all components with DI water to remove

Page 11

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 19  Thread shuttle cap onto detent adapter hand tight. Figure 4-4 ATTENTION: Threads should

Page 12

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL CONTENTS CONTENTS 1 INSTALLATION ...

Page 13 - 4.3 TOOLS

PAGE 20 MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL Figure 4-5  Remove shaft insert tool and thread second push plate onto main shaft. Tig

Page 14 - 4.4 PARTS ILLUSTRATION

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 21  Reinstall transfer tubes in head ports using latex gloves for added grip. Ensure transfe

Page 15 - 4.6 CLEAN-UP

PAGE 22 MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL 5 TROUBLESHOOTING Pump Will Not Start, Fails to Operate Cause: Solution: Insufficient ai

Page 16 - 4.7 DISASSEMBLY

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 23 6 WARRANTY See the Trebor Standard Limited Warranty at www.idex-hs.com/support/trebor/dow

Page 17 - 4.7.a Body Disassembly

PAGE 24 MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL 7 CONTACT INFORMATION 7.1 GENERAL CONTACT INFORMATION Web: www.treborintl.com Pho

Page 18 - 4.8 ASSEMBLY

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 3 1 INSTALLATION 1.1 UNPACKING After unpacking, the pump should be checked for any damage tha

Page 19 - 4.8.b Body Assembly

PAGE 4 MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL Figure 1-1 ATTENTION: The pump should be operated with clean, dry air or nitrogen. Partic

Page 20 - 4.8.c Final Assembly

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 5 1.3 REMOTE EXHAUST HOOK-UP  Remove existing Muffler Assembly from pump base.  Install Ex

Page 21

PAGE 6 MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL 2 OPTIONS 2.1 FLUID PORT CONNECTION OPTIONS All M50R pumps with –X12 option have integra

Page 22 - 5 TROUBLESHOOTING

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 7 2.3 OPTIONAL LEAK SENSING 2.3.a Installation  Remove plug seal from port. Probe is self-

Page 23 - 6 WARRANTY

PAGE 8 MAXIM 50R-X12 PUMP OPERATION / MAINTENANCE MANUAL 3 START-UP  Pump air supply pressure must be regulated. (See Figure 3-2: Pressure vs. F

Page 24 - 7 CONTACT INFORMATION

MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 9 Figure 3-1: Pressure & Capacity Chart NOTE: Test information is based on specific condit

Commentaires sur ces manuels