SERIAL NUMBER (located on top of product): PATENTS: U.S. 09642426, U.S. 06106246, U.S. 05971402, U.S. 05370507 07/27/2012 – MM50R-F Phone: 800-669
PAGE 10 MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL 4 MAINTENANCE Trebor pump maintenance can be divided into two categories: air system maintena
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 11 MAXIM 50R Maintenance Schedule Install 30 Days 3 Months 6 Months 9 Months 12 Months 15 Mont
PAGE 12 MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL 4.1.a Preventive Maintenance Record Company Name: ___________________________________________
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 13 4.2 RECOMMENDED SPARE PARTS KR50R-00-A Spares Rebuild Kit, which includes: Part No Qty Desc
PAGE 14 MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL 4.4 PARTS ILLUSTRATION
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 15 4.5 PARTS LIST ILL NO PART NO QTY DESCRIPTION PM YEAR # MATERIAL 1 AM075 1 Damper Plug PTF
PAGE 16 MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL 4.7 DISASSEMBLY During the life of the pump it will be necessary to perform certain preventat
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 17 To remove diaphragms, slit diaphragm with a sharp knife and pull the diaphragms from the
PAGE 18 MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL 4.7.d Cleaning Gently spray clean or dunk rinse all components with DI water to remove any
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 19 Thread shuttle cap onto detent adapter, torque to 40in-lbs. hand tight. Figure 4-4 ATTEN
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL CONTENTS CONTENTS 1 INSTALLATION ...
PAGE 20 MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL Figure 4-5 Remove shaft insert tool and thread second push plate until engagement with the
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 21 Wrap each transfer tube with 3 wraps of Teflon tape and reinstall into the head ports usi
PAGE 22 MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL 4.9 TESTING 4.9.a Performance Test With the air supply at 0 psi open the air supply valv
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 23 5 TROUBLESHOOTING Pump Will Not Start, Fails to Operate Cause: Solution: Insufficient air
PAGE 24 MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL 6 WARRANTY See the Trebor Standard Limited Warranty at www.idex-hs.com/support/trebor/downl
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 25 7 CONTACT INFORMATION 7.1 GENERAL CONTACT INFORMATION Web: www.treborintl.com Phone
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 3 1 INSTALLATION 1.1 UNPACKING After unpacking, the pump should be checked for any damage tha
PAGE 4 MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL Figure 1-1 ATTENTION: The pump should be operated with clean, dry air or nitrogen. Particula
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 5 1.3 REMOTE EXHAUST HOOK-UP Remove existing Muffler Assembly from pump base. Install Ex
PAGE 6 MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL 2 OPTIONS 2.1 FLUID PORT CONNECTION OPTIONS NOTE: Use O-ring to seal stainless steel or other
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 7 NOTE: See Surge Suppressor Operation Manual for detailed installation instructions. 2.3 OPT
PAGE 8 MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL 3 START-UP Pump air supply pressure must be regulated. (See Figure 3-2: Pressure vs. Fluid
MAXIM 50R PUMP OPERATION / MAINTENANCE MANUAL PAGE 9 Figure 3-1: Pressure & Capacity Chart NOTE: Test information is based on specific condit