SERIAL NUMBER (located on top of product):
PATENTS: U.S. 09642426, U.S. 06106246, U.S. 05971402, U.S. 05370507 07/27/2012 MM50EU-F
Phone: 800-669-1303 or 801-561-0303
Fax: 801-255-2312
MAXIM 50E/U PUMP
External Controlled
Operation / Maintenance
Manual
Vue de la page 0
1 2 3 4 5 6 ... 32 33

Résumé du contenu

Page 1 - MAXIM 50E/U PUMP

SERIAL NUMBER (located on top of product): PATENTS: U.S. 09642426, U.S. 06106246, U.S. 05971402, U.S. 05370507 07/27/2012 – MM50EU-F Phone: 800-66

Page 2 - CONTENTS

PAGE 10 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL Figure 3-1: Pressure & Capacity Chart NOTE: Test information is based on specific condi

Page 3 - 1 INSTALLATION

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 11 4 MAINTENANCE Trebor pump maintenance can be divided into two categories: air system main

Page 4

PAGE 12 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL MAXIM 50E and 50U Maintenance Schedule Install 30 Days 3 Months 6 Months 9 Months 12 Months

Page 5 - 1.4 PLC CONTROL SCHEMATIC

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 13 4.1.a Preventive Maintenance Record Company Name: _______________________________________

Page 6 - 1.5 REMOTE EXHAUST HOOK-UP

PAGE 14 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL 4.2 RECOMMENDED SPARE PARTS KR50EU-00-A Spares Rebuild Kit, which includes: Part No Qty Des

Page 7 - 2 OPTIONS

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 15 4.4 PARTS ILLUSTRATION

Page 8 - 2.3 OPTIONAL LEAK SENSING

PAGE 16 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL 4.5 PARTS LIST ILL NO PART NO QTY DESCRIPTION PM YEAR # MATERIAL 1 AK003-01 2 Union Nut PV

Page 9 - 3 START-UP

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 17  Loosen and remove probe caps (Probes included with E Model only) from heads using 3/4”

Page 10

PAGE 18 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL  Unscrew push plate from the shaft in a counter-clockwise direction. Pull other push plat

Page 11 - 4 MAINTENANCE

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 19 Figure 4-3  Install muffler assembly using the 1” pin tool, torque to 40in-lbs. 4.8.b

Page 12

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL CONTENTS CONTENTS 1 INSTALLATION ...

Page 13

PAGE 20 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL Figure 4-4  Remove shaft insert tool and thread second push plate until engagement with t

Page 14 - 4.3 TOOLS

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 21  Wrap each transfer tube with 3 wraps of Teflon tape and reinstall into the head ports u

Page 15 - 4.4 PARTS ILLUSTRATION

PAGE 22 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL 4.9 TESTING 4.9.a Performance Test  Start with air regulator at low (< 15 psi) press

Page 16 - 4.7 DISASSEMBLY

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 23 4.10 MAXIM PUMP LADDER LOGIC CONTROL EXAMPLE The following sample ladder logic is provide

Page 17

PAGE 24 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL !SPEED ! !

Page 18 - 4.8 ASSEMBLY

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 25 ! +------------------------------------------------------[RST M12 ]+ !

Page 19 - 4.8.b Body Assembly

PAGE 26 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL ! ! !

Page 20 - 4.8.c Final Assembly

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 27 ! ! !

Page 21

PAGE 28 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL 0 +-I I--------------------------------------------------------[SET M8028]+ !ON

Page 22 - 4.9 TESTING

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 29 17 +-I I-+-I I-+------------------------------------------------[SET M11 ]+ !PL

Page 23

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 3 1 INSTALLATION 1.1 UNPACKING After unpacking, the pump should be checked for any damage t

Page 24

PAGE 30 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL 35 +-I I-+------------------------------------------------------[RST T42 ]+ !

Page 25 - 4.10.b End-Of-Stroke Control

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 31 5 TROUBLESHOOTING Pump Will Not Start, Fails to Operate Cause: Solution:  Insufficient

Page 26

PAGE 32 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL 6 WARRANTY See the Trebor Standard Limited Warranty at www.idex-hs.com/support/trebor/dow

Page 27

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 33 7 CONTACT INFORMATION 7.1 GENERAL CONTACT INFORMATION Web: www.treborintl.com Pho

Page 28

PAGE 4 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL Figure 1-1 ATTENTION: The pump should be operated with clean, dry air or nitrogen. Particu

Page 29

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 5 1.3 PROBE ASSEMBLY INSTALLATION (E MODEL ONLY) Optic Cable: 1mm core; 1/4” PFA protective

Page 30

PAGE 6 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL Figure 1-3 1.5 REMOTE EXHAUST HOOK-UP  Remove existing Muffler Assembly from pump base. 

Page 31 - 5 TROUBLESHOOTING

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 7 2 OPTIONS 2.1 FLUID PORT CONNECTION OPTIONS NOTE: Use O-ring to seal stainless steel or o

Page 32 - 6 WARRANTY

PAGE 8 MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL NOTE: See Surge Suppressor Operation Manual for detailed installation instructions. 2.3 OPTI

Page 33 - 7 CONTACT INFORMATION

MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL PAGE 9 3 START-UP  Pump air supply pressure should be regulated. (See : Pressure vs. Fluid Tem